Blog Categories
- Appliances Four
- Athletic Seating
- Auto Helpers
- Automated Stock Rooms
- Chocolate Four
- CuraFlo
- Damaged Goods Dating
- Flood Insurance Four
- Game Addict
- Hi Tech Pest Control
- HVAC Four
- Medical Labels Four
- Mental Health Four
- National CWS
- Promotional Ideas
- Seguros Lara Insurance
- Stem Cell Worx
- The Hidden Truth
- The Last Refuge
- The Mozilla Blog
- Video Editing Four
- Web Design Dev
- Website Development Four
- Windows Blog
HVAC Four
Heating, ventilation, and air conditioning is the technology of indoor and vehicular environmental comfort. Its goal is to provide thermal comfort and acceptable indoor air quality.
Posted On: October 30, 2020
If you’re looking for help fixing your Heil furnace, look no further! Our comprehensive Heil furnace repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: LED flashing like a heartbeat
PROBLEM: Control has 24 VAC power
FIX: n/a
CODE: Two LED flashes
PROBLEM: Unit’s pressure switch didn’t open
FIX: Check for an obstruction in the pressure tubing
CODE: Three LED flashes
PROBLEM: Unit’s pressure switch didn’t close or reopened
FIX: Check for: excessive wind; if i...[More]Posted On: October 30, 2020
If you’re looking for help fixing your Heil furnace, look no further! Our comprehensive Heil furnace repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: LED flashing like a heartbeat
PROBLEM: Control has 24 VAC power
FIX: n/a
CODE: Two LED flashes
PROBLEM: Unit’s pressure switch didn’t open
FIX: Check for an obstruction in the pressure tubing
CODE: Three LED flashes
PROBLEM: Unit’s pressure switch didn’t close or reopened
FIX: Check for: excessive wind; if i...[More]Posted On: October 24, 2020
If you’re looking for help fixing your Coleman air conditioner, look no further! Our comprehensive Coleman air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: E0.
PROBLEM: Indoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error.
CODE: E1.
PROBLEM: Indoor and outdoor unit communication malfunction.
CODE: E3.
PROBLEM: Indoor fan speed malfunction.
CODE: E4.
PROBLEM: Indoor room temperature sensor error.
CODE: E5.
PROBLEM: Evaporator c...[More]Posted On: October 24, 2020
If you’re looking for help fixing your Coleman air conditioner, look no further! Our comprehensive Coleman air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: E0.
PROBLEM: Indoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error.
CODE: E1.
PROBLEM: Indoor and outdoor unit communication malfunction.
CODE: E3.
PROBLEM: Indoor fan speed malfunction.
CODE: E4.
PROBLEM: Indoor room temperature sensor error.
CODE: E5.
PROBLEM: Evaporator c...[More]Posted On: October 23, 2020
If you’re looking for help fixing your Tempstar air conditioner, look no further! Our comprehensive Tempstar air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: A1.
PROBLEM: Malfunction of indoor unit PCB Malfunction due to noise Defect of indoor unit PCB.
CODE: A3.
PROBLEM: Malfunction of drain level control system Drain piping clogging, improper drain piping work Defect of drain pump. Defect of float switch.
CODE: A4.
PROBLEM: Malfunction of freezi...[More]Posted On: October 23, 2020
If you’re looking for help fixing your Tempstar air conditioner, look no further! Our comprehensive Tempstar air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: A1.
PROBLEM: Malfunction of indoor unit PCB Malfunction due to noise Defect of indoor unit PCB.
CODE: A3.
PROBLEM: Malfunction of drain level control system Drain piping clogging, improper drain piping work Defect of drain pump. Defect of float switch.
CODE: A4.
PROBLEM: Malfunction of freezi...[More]Posted On: October 17, 2020
If you’re looking for help fixing your Payne air conditioner, look no further! Our comprehensive Payne air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
OPERATION LAMP: Flashing.
TIMER LAMP: Off.
PROBLEM: Indoor fan speed has been out of control for over 1 minute.
OPERATION LAMP: Flashing.
TIMER LAMP: On.
PROBLEM: Indoor room temp. or evaporator sensor is open circuit or short circuited.
OPERATION LAMP: Off.
TIMER LAMP: Flashing.
PROBLEM: Compressor o...[More]Posted On: October 17, 2020
If you’re looking for help fixing your Payne air conditioner, look no further! Our comprehensive Payne air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
OPERATION LAMP: Flashing.
TIMER LAMP: Off.
PROBLEM: Indoor fan speed has been out of control for over 1 minute.
OPERATION LAMP: Flashing.
TIMER LAMP: On.
PROBLEM: Indoor room temp. or evaporator sensor is open circuit or short circuited.
OPERATION LAMP: Off.
TIMER LAMP: Flashing.
PROBLEM: Compressor o...[More]Posted On: October 16, 2020
If you’re looking for help fixing your Ruud air conditioner, look no further! Our comprehensive Ruud air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: Green “POWER”.
PROBLEM: Module has power.
FIX: Supply voltage is present at module terminals.
CODE: Red “TRIP”.
PROBLEM: Thermostat demand signal Y1 is present, but the compressor is not running.
FIX: Compressor internal overload is open. Broken wire or connector is not making contact. Low pr...[More]Posted On: October 16, 2020
If you’re looking for help fixing your Ruud air conditioner, look no further! Our comprehensive Ruud air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: Green “POWER”.
PROBLEM: Module has power.
FIX: Supply voltage is present at module terminals.
CODE: Red “TRIP”.
PROBLEM: Thermostat demand signal Y1 is present, but the compressor is not running.
FIX: Compressor internal overload is open. Broken wire or connector is not making contact. Low pr...[More]tempstar air conditioner codes
Posted On: October 10, 2020
If you’re looking for help fixing your Tempstar air conditioner, look no further! Our comprehensive Tempstar air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: On solid, no flash
PROBLEM: Normal operation � with communicating Control.
CODE: Off
PROBLEM: Normal operation � No call for cooling with 2-wire connection or indoor unit not pow-Offered.
CODE: 1 pause
PROBLEM: Normal operation.
CODE: 16
PROBLEM: Communication with wall control lost. Chec...[More]tempstar air conditioner codes
Posted On: October 10, 2020
If you’re looking for help fixing your Tempstar air conditioner, look no further! Our comprehensive Tempstar air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: On solid, no flash
PROBLEM: Normal operation � with communicating Control.
CODE: Off
PROBLEM: Normal operation � No call for cooling with 2-wire connection or indoor unit not pow-Offered.
CODE: 1 pause
PROBLEM: Normal operation.
CODE: 16
PROBLEM: Communication with wall control lost. Chec...[More]Posted On: October 9, 2020
If you’re looking for help fixing your Luxaire air conditioner, look no further! Our comprehensive Luxaire air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: E0.
PROBLEM: Indoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error.
CODE: E1.
PROBLEM: Indoor and outdoor unit communication malfunction.
CODE: E3.
PROBLEM: Indoor fan speed malfunction.
CODE: E4.
PROBLEM: Indoor room temperature sensor error.
CODE: E5.
PROBLEM: Evaporator c...[More]Posted On: October 9, 2020
If you’re looking for help fixing your Luxaire air conditioner, look no further! Our comprehensive Luxaire air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: E0.
PROBLEM: Indoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error.
CODE: E1.
PROBLEM: Indoor and outdoor unit communication malfunction.
CODE: E3.
PROBLEM: Indoor fan speed malfunction.
CODE: E4.
PROBLEM: Indoor room temperature sensor error.
CODE: E5.
PROBLEM: Evaporator c...[More]continental air conditioner codes
Posted On: October 4, 2020
If you’re looking for help fixing your Continental air conditioner, look no further! Our comprehensive Continental air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: Unit will not operate.
PROBLEM: Power disconnected or loose connection.
FIX: Check voltage at contactor.
CODE: Unit will not operate.
PROBLEM: Blown fuse / breaker tripped.
FIX: Replace fuses / reset breaker.
CODE: Unit will not operate.
PROBLEM: Thermostat out of calibration is set too...[More]continental air conditioner codes
Posted On: October 4, 2020
If you’re looking for help fixing your Continental air conditioner, look no further! Our comprehensive Continental air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: Unit will not operate.
PROBLEM: Power disconnected or loose connection.
FIX: Check voltage at contactor.
CODE: Unit will not operate.
PROBLEM: Blown fuse / breaker tripped.
FIX: Replace fuses / reset breaker.
CODE: Unit will not operate.
PROBLEM: Thermostat out of calibration is set too...[More]napoleon air conditioner codes
Posted On: October 3, 2020
If you’re looking for help fixing your Napoleon air conditioner, look no further! Our comprehensive Napoleon air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: Unit will not operate,
PROBLEM: Power disconnected or loose connection.
FIX: Check power supply to unit. Check voltage at contactor.
CODE: Unit will not operate,
PROBLEM: Blown fuse / breaker tripped.
FIX: Replace fuses/reset breaker.
CODE: Unit will not operate,
PROBLEM: Thermostat out of ca...[More]napoleon air conditioner codes
Posted On: October 3, 2020
If you’re looking for help fixing your Napoleon air conditioner, look no further! Our comprehensive Napoleon air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: Unit will not operate,
PROBLEM: Power disconnected or loose connection.
FIX: Check power supply to unit. Check voltage at contactor.
CODE: Unit will not operate,
PROBLEM: Blown fuse / breaker tripped.
FIX: Replace fuses/reset breaker.
CODE: Unit will not operate,
PROBLEM: Thermostat out of ca...[More]Posted On: September 27, 2020
If you’re looking for help fixing your ComfortMaker furnace, look no further! Our comprehensive ComfortMaker furnace repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: Steady LED flashing
PROBLEM: Normal operation
FIX: n/a
CODE: Two LED flashes
PROBLEM: Pressure switch stuck closed
FIX: Obstruction in pressure tubing
CODE: Three LED flashes
PROBLEM: Pressure switch stuck open or manual ON/OFF switch in off position
FIX: Proper vent size; defective inducer motor; ex...[More]Posted On: September 27, 2020
If you’re looking for help fixing your ComfortMaker furnace, look no further! Our comprehensive ComfortMaker furnace repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.
CODE: Steady LED flashing
PROBLEM: Normal operation
FIX: n/a
CODE: Two LED flashes
PROBLEM: Pressure switch stuck closed
FIX: Obstruction in pressure tubing
CODE: Three LED flashes
PROBLEM: Pressure switch stuck open or manual ON/OFF switch in off position
FIX: Proper vent size; defective inducer motor; ex...[More]